( 1) The number of cabinet: 10 sets.
( 2) Conditions of use ( a) Working temperature: - 5℃ ~ 40℃ ( b) Relative humidity: 85% (or less +3℃)
( 3) The appearance and structure ( a) Cabinet appearance size high x width x: 2000 * 600 * 1000 mm, net installation height of 42 u ( b) Color: RAL9005 ( Black) 。 ( c) Cabinet material: framework using ninety percent package edge profile ( A single piece of steel plate rolling molding) The materials of 2. 0 mm cold rolled steel sheet. Easy to install, 10 profiles. 5x12. 4 5 square hole and diameter. 5 the round hole, the modulus of 25 mm. Single cabinet bearing not less than 1000 kg. ( d) Firm structure, assembly has consistency and interchangeability, no loose fasteners. ( e) Mechanical parts meet the flexible rotation, reasonable, reliable locking plug, construction installation and maintenance is convenient. ( f) Uniform coating layer surface is smooth, colour and lustre, sag, grinning, without burr, rust of the metal.
( 4) Electrical performance ( a) In 20 + / - 5 ℃ environment temperature, relative humidity is not more than 80% of the conditions, any of the same insulation between terminals, terminal blocks of the insulation resistance between the casing and meet more than 1 m ohm. ( b) Any vary between terminals, terminal blocks between the casing and meet in ac 50 hz RMS 2000 v ac voltage, breakdown and lasted 1 minute no flashover phenomenon.
( 5) Cabinet structure form and material ( a) Cabinet cabinet using custom specifications, mesh sheet open the front door and back door with double open mesh take off discharge type structure, because the computer room air conditioning for the underfloor air supply, so the cabinet bottom left between free convenient air conditioning cold wind blow; Side door to the take off discharge type structure, no mesh, at the top of the mesh. ( b) Before and after the door plank material of 2. 0 mm cold rolled steel sheet. In order to ensure the door not shake, in door must have a hollow square steel as strengthening rod. To ensure close tightly, on the door must have a PU foam sealing strip of foam molding directly, and not to tear off the sealing strip has no joint. About the design of the gate must ensure that the direction of the door can change quickly. Door adopt the die casting aluminum alloy 130 - degree quickly remove the hinge. Door lock for a single point of die casting aluminum alloy lock with a key, the back door to the three point lock structure. ( c) Side panel material is 1. Imported cold rolled steel, 5 mm on the side panel is PU foam sealing strip of foam molding directly, and not to tear off the sealing strip has no joint. And the cabinet frame fixed with no rapid installation tools. ( d) Roof material for import 1. 5 mm cold rolled steel sheet to ensure that the roof not rock, on the roof must be PU foam sealing strip of foam molding directly, and not to tear off the sealing strip has no joint. And the cabinet frame fixed with screw connection. To walk the line, on the roof to set 2 100 round hole diameter, need not when can use plastic cover seal. At the bottom of the set must be beneficial to into the line. Bottom and top single direction for not less than 200 root ( Six lines) 。 Roof top round vent. ( e) 19 'installation Angle gauge must be installed can adjust depth, a total of 4 before and after the root. For ease of installation, pillar scale must be U. ( f) Each cabinet should be equipped with different sizes go line accessories, need to implement vertical direction go line, line ring size is 60 mm and 120 mm * 80 mm * 40 mm optional. ( g) Each cabinet is equipped with 2 sets PDU, request power supply output 10 league, IEC 320 C13 input socket for IEC320 C09 socket type, and 16 a current, the rated working voltage of 4000 w, has the overload protection function, frame type installation. ( h) Each cabinet is equipped with a number of fixed tray and slide plate, in order to ensure the safety of equipment, bearing at least for more than 50 kg. ( i) Each cabinet should be equipped with four nuts, screws 50 vice. ( j) Will need to be equipped with corresponding side panel.
( 6) Cabinet cooling, cabinet meet good ventilation and heat dissipation. Then ventilated area of not less than 65% of the area.
( 7) Cabinet met the requirement of the surface treatment for protection on the surface of the cabinet, the surface treatment according to the following process: the process of pickling, phosphating - Dry - Electrophoretic infiltration primer: color RAL9005, thickness - 20 microns Dry - Powder coating, the color according to the requirement, the thickness of 80 ~ 100 microns ( All after spraying, the total coating thickness to reach 90 ~ 135 microns) 。
( 8) Cabinet cabinet, the cabinet and ark can IBM DELL cabinet and cabinet, was laid with good original server rack links. The cabinet also can use IBM and DELL rack sides.
three cabinets cabinets we are production factory, can according to drawings, may request your we tailor-made to help you design and processing, quality assurance, the price is cheap. May offer at any time, the national advisory telephone:.
charging cart,charge cart,charging trolley,charging station ,network cabinet,server rack are all following the most compatible manufacturing regulations.
Through our culture, our drive and the expertise of each individual employee, NINGBO LONGTU NETWORK TECHNOLOGY CO.,LTD. is uniquely positioned to provide best-in-class services to a global customer base.
charging cart,charge cart,charging trolley,charging station ,network cabinet,server rack provider at TNE Charging cart Network Cabinet charge cart offers a wide variety of in many options. quality is absolutely ensured if you choose us. welcome to visit our factory.
Custom message
Chat Online
Chat Online
Chat Online inputting...